Welcome to Professional Affinity

System version 3.4c

Welcome to Milliman's Professional Affinity system.  Read on to learn more about this release of Affinity, to get support, and to send feedback to the software team.

 

 What's new in Professional Affinity 3.4c

Fix to PWGrowToDiag function
An error was fixed in the Affinity PWGrowToDiag function.  This function detrends the latest diagonal by a selected trend factor, and it was using the incorrect trend factor. For example, if the trend at 12 months is 8.0% and the trend at 24 months is 4.0%, the triangle points at 12 months will be detrended based on the 24 month trend factor of 4.0% instead of the correct 12 month trend of 8.0%.

The only standard Affinity template that uses this function can be found within the Affinity user interface in the Templates tab under the Berquist-Sherman Methods folder.  The template is called "Change in Case Reserve Adequacy," and its default Excel sheet name is "BSMDATA1."

However, also be aware that any custom templates you may have built based on the standard Changes in Case Reserve Adequacy template will also be affected by this issue.

This error was introduced with the release of Affinity Professional Version 3.4.  The patch containing this fix is only necessary for those users who have upgraded to that version (typically, users who needed the upgrade to work with Excel 2007 or who have USB hardware keys).

Not that this is a patch to be applied to an existing installed system; this is not a full system release.

 

 
 Get support

Our Web site contains the latest Frequently Asked Questions from our many users about using and getting the most from Professional Affinity. It also provides information about any potential issues or updates that may be available, and gives you a direct connection to our support experts.

Feel free to call us any time with any questions, or if we can help you use our solution more efficiently. Trained technical and actuarial experts are available Monday through Friday, 8:30 am to 5 pm Eastern U.S. time, excluding holidays. They will be happy to walk you through solutions or troubleshoot problems, usually within a matter of minutes. Our Customer Hotline numbers are:

 

 
 Send feedback

Send wishes (feature and change requests) to the Affinity Team. We'll do our best to make them come true. We will reply to all messages, thoughts and ideas.

Send bugs directly to us. We definitely want to hear about any challenges you encounter while using Professional Affinity.

 
Thanks!
The Professional Affinity Team

 

 

 

 

 
Notes from prior release
 

Version 3.4

Microsoft Excel 2007

Microsoft made changes in their release of Excel 2007 that affected how certain functions work in Professional Affinity.  As a result, there were potential issues with the calculation of volume-weighted averages, the PWTail function, and certain curve fit charts.  These have all been resolved with this latest release.  Version 3.4 should be installed on any computer running Microsoft Office or Excel 2007.

New Installation

These changes also required that we provide a new installation routine for the system. Beginning with version 3.4, you will need to enter a serial number at the time of installation.